NAV6 PSU Isolator

DDi Series Voltage Converters

The DDi Series of PSU's available from ICS can be used to stabilise your voltage or isolate your supply.

These 12V units are ideal for small marine craft and a variety of industrial uses. This unit is ideal for powering the NAV6 NAVTEX System range.

NAV6 PSU Isolator

DDi Series Voltage Converters Features

A list of features for the PSU Converter are listed below:

  • Ideal for small vehicles such as marine craft.
  • 12V-12V unit provides a stable output voltage as well as providing galvanic isolation for a variety of application.
  • Click ‘n’ fit’ mounting clip which is fixed in three points allowing it to be mounted on uneven surfaces. 
  • No ventilation holes to permit stray objects, dust or water droplets to enter the case.
  • Red LED indicates when there is output from the converter.
  • No external fuses.
  • Enclosed in a rugged aluminium extrusion.
  • Vibration and shock proof.

Technical Specification

ICS Part Number ICS.500.09
Manufacturer Alphatronix
Model DDi 12-12 036
Power 36W (3A) Isolated
Nominal Voltage 12Vdc input, 12Vdc output
Dimensions 89 x 87 x 50mm
Weight 290g
Input Voltage Range 12Vdc, 24Vdc and 48Vdc +/- 30%
Output Voltage 13.6Vdc or 27.2Vdc +15% -20% at extremes of temperature, load, input tolerance, etc.
Intermittent output power As stated, taken for a maximum of 2 minutes followed by 8 minutes rest.
Transient voltage protection Meets !SO7637-2 International standard for 24Vdc commercial vehicles.
Electrostatic voltage protection Meets ISO10605, ISO14892, >8kV contact, 15kV discharge.
Output noise <50mV pk-pk (100mV on 24V units) at continuous load. Meets CISPR25 and VDE0879-3
Off load current
(quiescent current)
<100mA
Power conversion efficiency Typically: 90% for non-isolated units, 85% for isolated units.
Isolation >400Vrms between input, output and case, on isolated products only.
Operating temperature -25ºC to +30ºC to meet this specification table
+30ºC to +80ºC de rate linearly to 0A
Storage temperature -25ºC to +100ºC
​Operating humidity 95% max. non-condensing
Casework Anodised aluminium, glass filled polycarbonate, dust water and impact resistance to IP533 (excludes DDi 24-24 240 which is ventilated and fitted with a cooling fan).
Connections Four 6.3mm push-on flat blade connectors.
Output indicator Red LED adjacent to output terminals.
Mounting method Click ‘n’ fit mounting clip, fitted separately using three hole fixing
Safe area protection: Over current Limited by current sensing circuit.
Over heat Limited by temperature sensing circuit.
Transients Protected by filters and rugged component selection.
Catastrophic failure Protected by internal input and output fuses.
Approvals 2004/108/EC The general EMC directive
2006/96/EC The automotive directive
93/68/EEC The CE marking directive
Markings CE and e marked