ICS Part Number |
ICS.500.09 |
Manufacturer |
Alphatronix |
Model |
DDi 12-12 036 |
Power |
36W (3A) Isolated |
Nominal Voltage |
12Vdc input, 12Vdc output |
Dimensions |
89 x 87 x 50mm |
Weight |
290g |
Input Voltage Range |
12Vdc, 24Vdc and 48Vdc +/- 30% |
Output Voltage |
13.6Vdc or 27.2Vdc +15% -20% at extremes of temperature, load, input tolerance, etc. |
Intermittent output power |
As stated, taken for a maximum of 2 minutes followed by 8 minutes rest. |
Transient voltage protection |
Meets !SO7637-2 International standard for 24Vdc commercial vehicles. |
Electrostatic voltage protection |
Meets ISO10605, ISO14892, >8kV contact, 15kV discharge. |
Output noise |
<50mV pk-pk (100mV on 24V units) at continuous load. Meets CISPR25 and VDE0879-3 |
Off load current
(quiescent current) |
<100mA |
Power conversion efficiency |
Typically: 90% for non-isolated units, 85% for isolated units. |
Isolation |
>400Vrms between input, output and case, on isolated products only. |
Operating temperature |
-25ºC to +30ºC to meet this specification table
+30ºC to +80ºC de rate linearly to 0A |
Storage temperature |
-25ºC to +100ºC |
Operating humidity |
95% max. non-condensing |
Casework |
Anodised aluminium, glass filled polycarbonate, dust water and impact resistance to IP533 (excludes DDi 24-24 240 which is ventilated and fitted with a cooling fan). |
Connections |
Four 6.3mm push-on flat blade connectors. |
Output indicator |
Red LED adjacent to output terminals. |
Mounting method |
Click ‘n’ fit mounting clip, fitted separately using three hole fixing |
Safe area protection: Over current |
Limited by current sensing circuit. |
Over heat |
Limited by temperature sensing circuit. |
Transients |
Protected by filters and rugged component selection. |
Catastrophic failure |
Protected by internal input and output fuses. |
Approvals |
2004/108/EC The general EMC directive
2006/96/EC The automotive directive
93/68/EEC The CE marking directive |
Markings |
CE and e marked |